Welcome to
Applications - Dog Kennels
Equipment
Selection: Use low to mid-sized BTU infra-red
tube heaters, not to exceed 40 ft. or 100,000 BTU. DBS
Series and/or HL Series Heaters are typically best
suited for these applications. Heaters should be
controlled by thermostat, with sensors at the animals'
level. Care should be taken not to use oversized
heaters.
Installation:
To heat dual facing rows of cages (typical), place the
heaters along the center line of the building, about
8-10 ft. above the floor. Mount tube burner boxes near
the areas with highest heat loss (doors). Optimum
coverage heats about half of each cage, which allows the
animals to move to and from the heat as desired.
Combustion air is highly recommended. All heaters
should be vented.